| Sign In | Join Free | My spintoband.com |
|
Brand Name : HBYIQI
Model Number : HB-DC06-B-150L
Certification : CE, ISO-9001
Place of Origin : China
MOQ : 1 set
Price : Negotiation
Payment Terms : T/T
Delivery Time : 15 days
Packaging Details : International Standard Package
Model : HB-DC06-B-150L
Temperature range : -10℃~+80℃(Adjustable)
Heating rate : Average 3℃/min
Cooling rate : Average 3℃/min
Inner box size : W500*D500*H600mm
Outer box size : W700*D900mm*H1800
Battery Testing Equipment
Brand: HBYIQI
Equipment Name: Battery Forced Internal Short Circuit Tester
Standard basis: UL1642, GB 31241-2022
Application:
Battery forced internal short circuit tester simulates the short circuit caused by metal particles that may occur inside the battery during the production process, and evaluate the safety performance of the battery under such circumstances.
Technical Parameter
| Model | HB-DC06-B-150L |
| Temperature Chamber | |
| Control Mode | PLC |
| Temperature range | -10℃~+80℃(Adjustable) |
| Heating rate | Average 3℃/min (from -10℃ to 80℃, nonlinear no-load) |
| Cooling rate | Average 3℃/min (from 80℃ to -10℃, nonlinear no-load) |
| Inner box size | W500*D500*H600mm |
| Outer box size | W700*D900mm*H1800 |
| Inner box material | Mirror stainless steel plate, reinforced at bottom |
| Exterior box material | Cold rolled steel paint treatment |
| Visual window | The single door is equipped with a 3-layer vacuum large glass observation window (W270*H350mm); The door frame is equipped with electric heating (automatic adjustment) to prevent frost and condensation; So that you can observe the test status of the test sample in the box at any time through the observation window clearly. |
| Internal Short Circuit Standard | |
| Control mode | PLC |
| Maximum load | 200KG |
| Value resolution | 1/10000 |
| Force value accuracy | ≤0.5% |
| Displacement resolution | 1/1000 |
| Displacement accuracy | ≤0.5% |
| Speed range | 0.01-5mm/s |
| Limited travel | 0-200mm |
| Maximum test plane | 300x300mm (Special test width can also be customized according to customer requirements |
| Voltage collection range | 0-60V |
| Voltage resolution | 5mV |
| Voltage acquisition frequency | 100Hz |
| Input Power Requirement | |
| Work Voltage | AC 220V 50Hz or Customization Accepted |
| Power | 6KW |
| Optional Parts(Extra Charge) | |
| Addable item | Add temperature acquisition channel, voltage acquisition system, video surveillance system, smoke alarm system, fire extinguishing system(euipment provided by user). |